Powered by GoogleTranslate

Inspection Detail

Inspection: 107182362 - American Environmental Contractors Inc.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 107182362
Report ID: 0418100
Date Opened: 02/10/1993

Site Address:
American Environmental Contractors Inc.
Intersection Of Hwy 13 & Hwy 120
Duluth, GA 30136

Mailing Address:
P.O. Box 1274, Covington, GA 30209

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/16/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/28/1993


Related Activity
Type Activity Nr Safety Health
Referral 901681809 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $2,700 $0 $0 $0 $0 $2,700
Current Penalty $2,700 $0 $0 $0 $0 $2,700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260059 E01 04/26/1993 04/29/1993 $600 $600 $0 -  
2. 01001B Serious 19260059 G01 04/26/1993 04/29/1993 $0 $0 $0 -  
3. 01002A Serious 19260352 I 04/26/1993 04/29/1993 $1,500 $1,500 $0 -  
4. 01002B Serious 19260020 B01 04/26/1993 04/29/1993 $0 $0 $0 -  
5. 01003 Serious 19261051 A 04/26/1993 04/29/1993 $600 $600 $0 -  
6. 02001 Other 19260152 A01 04/26/1993 05/09/1993 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 609263
Event: 02/10/1993
Employees injured in underground storage tank explosion

Employee #1 climbed atop an 8 ft diameter underground storage tank to spray petroleum dispersant inside the tank. Employee #2 began cutting an inspection hole in one end of the tank. No tests were performed within 10 minutes. Employee #2 made a 2 ft long horizontal cut, then had begun to make a 2 ft long vertical cut when a fire started and the tank exploded. The tank end blew out and away from where Employees #1 and #2 were located. Employee #1 fell to the paved parking lot, and suffered a broken knee cap. Employee #2 was slightly burned by the hot liquid sprayed from the tank. Employees #3 and #4, who were watching the process, were slightly injured. Employee #3 was struck in the face by debris and sustained minor cuts. Employee #4 fell to the ground and sustained a minor cut to his knee.

Keywords: BURN, KNEE, FRACTURE, CONSTRUCTION, STORAGE TANK, EXPLOSION, LACERATION, FALL, STRUCK BY, GASOLINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107182362 Non Hospitalized injury Fracture Occupation not reported
2 107182362 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 107182362 Non Hospitalized injury Cut/Laceration Occupation not reported
4 107182362 Non Hospitalized injury Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.