Inspection Detail
Inspection: 107180887 - Apt, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Apt, Inc.
Graywood Trace & Jones Bridge Circle
Norcross, GA 30092
Mailing Address:
3232 Cobb Parkway, Suite 506, Atlanta, GA 30339
Union Status: Union
SIC:7363
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 09/14/1993
Emphasis:
Case Closed: 11/04/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360450407 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19030002 A01 | 10/07/1993 | 10/13/1993 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 was working as a helper on the back of a municipal-type garbage truck and was performing garbage collection/pickup services. He became faint and his skin was hot to the touch. He was transported to a local hospital and admitted with a body temperature of 108 degrees F. He subsequently died of sequelar hyperthermia.
Keywords: GARBAGE TRUCK, HEAT STROKE, FAINTED, OVEREXPOSURE, HIGH TEMPERATURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107180887 | Occupation Not Listed |
Translate