Inspection Detail
Inspection: 107177727 - Heaton Erecting, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Heaton Erecting, Inc.
330 Macon Street
Mcdonough, GA 30253
Mailing Address:
507 Connafxa Road, Barnesville, GA 30253
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/06/1992
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/07/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 901179127 | Yes |
Investigation Summary
Employees #1, #2, #3 and a coworker were working on a partially decked roof truss system loading and storing bundles of 7/16 in. thick 4 ft by 8 ft wafer board onto the roof. One bundle of 45 sheets was already on the roof near Employees #2 and #3. The second bundle of 66 sheets was being placed approximately 8 ft away from Employee #1 and a coworker. As the second load was being set down, the truss system broke and Employees #2 and #3 fell approximately 27 ft to the floor. The roof truss system continued to collapse toward the break point until the entire truss system collapsed inside the building shell. Employee #1 was slightly injured as he escaped to another section of the roof, but neither he nor Employee #3 required hospitalization. Employee #2 was hospitalized.
Keywords: LOADING, COLLAPSE, FALL, FALL PROTECTION, UNSECURED, OVERLOADED, TRUSS, CONSTRUCTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107177727 | Occupation Not Listed |