Inspection Detail
Inspection: 107175903 - Picadilly Cafeteria
Inspection Information - Office: Atlanta East Area Office
Site Address:
Picadilly Cafeteria
3110 Washigton Road
Augusta, GA 30907
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5812
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/03/1992
Emphasis:
Case Closed: 12/16/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 901681502 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,125 | $0 | $0 | $0 | $0 | $1,125 |
| Current Penalty | $1,125 | $0 | $0 | $0 | $0 | $1,125 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19101200 E01 | 11/18/1992 | 12/21/1992 | $1,125 | $1,125 | $0 | - | ||
| 2. | 01001B | Serious | 19101200 H | 11/18/1992 | 12/21/1992 | $0 | $0 | $0 | - |
Investigation Summary
A defective gas valve orifice released an abnormal amount of natural gas into a water heater burner. The gas could not burn and was vented out along with the normal amount of exhaust. The exhaust vent pipe was too small to handle the excess gas and it flowed back to a weak section of the vent pipe where the accumulated carbon monoxide was released into the building. Employees #1 through #13 were exposed. Employees #8, #11, and #12 were hospitalized.
Keywords: VENTING, INHALATION, NATURAL GAS, EQUIPMENT FAILURE, AIR CONTAMINATION, VALVE, PIPE, WATER HEATER, CARBON MONOXIDE, MECH MALFUNCTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 2 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 3 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 4 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 5 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 6 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 7 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 8 | 107175903 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 9 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 10 | 107175903 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 11 | 107175903 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 12 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 13 | 107175903 | Non Hospitalized injury | Poisoning(Systemic) | Occupation not reported |
Translate