Inspection Detail
Inspection: 107117103 - Melroe Company
Inspection Information - Office: Bismarck Area Office
Site Address:
Melroe Company
210 First Avenue Ne
Gwinner, ND 58040
Mailing Address:
P.O. Box 128, Gwinner, ND 58040
Union Status: Union
SIC:3531
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 05/21/1993
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/05/1993
Type | Activity Nr | Safety | Health |
---|---|---|---|
Complaint | 74213893 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 06/17/1993 | 07/19/1993 | $2,500 | $5,000 | $0 | I - Informal Settlement |
Investigation Summary
Employees #1 and #2 were cleaning a liquid propane (lp) gas regulator on a heat treating furnace. Some lp gas was released and ignited, resulting in burns to the arms and hands of both employees. Employee #2 was hospitalized. The lp gas may have been ignited by either the burner or the pilot light on the heat treating furnace.
Keywords: BURN, FURNACE, REGULATOR VALVE, CLEANING, FIRE, LP GAS, GAS LEAK, PROPANE, ARM, HAND
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 107117103 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
2 | 107117103 | Non Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |