Inspection Detail
Inspection: 107114456 - Lake Preston Co-Op Association
Inspection Information - Office: Bismarck Area Office
Site Address:
Lake Preston Co-Op Association
106 Second Street Nw
Lake Preston, SD 57249
Mailing Address:
Box 338, Lake Preston, SD 57249
Union Status: NonUnion
SIC:5153
NAICS: 0
Inspection Type: Referral
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 09/03/1992
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/13/1993
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 901381442 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 1 | 5 | |||
Current Violations | 4 | 1 | 5 | |||
Initial Penalty | $2,100 | $0 | $0 | $0 | $0 | $2,100 |
Current Penalty | $2,100 | $0 | $0 | $0 | $0 | $2,100 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100025 D01 X | 10/22/1992 | 11/09/1992 | $300 | $300 | $0 | - | ||
2. | 01001B | Serious | 19100025 D02 I | 10/22/1992 | 11/09/1992 | $0 | $0 | $0 | - | ||
3. | 01002A | Serious | 19100157 C01 | 10/22/1992 | 11/09/1992 | $300 | $300 | $0 | - | ||
4. | 01002B | Serious | 19100157 C04 | 10/22/1992 | 11/09/1992 | $0 | $0 | $0 | - | ||
5. | 01002C | Serious | 19100157 E02 | 10/22/1992 | 11/09/1992 | $0 | $0 | $0 | - | ||
6. | 01002D | Serious | 19100157 G01 | 10/22/1992 | 11/09/1992 | $0 | $0 | $0 | - | ||
7. | 01003A | Serious | 19100272 I01 | 10/22/1992 | 10/29/1992 | $750 | $750 | $0 | - | ||
8. | 01003B | Serious | 19100272 I02 II | 10/22/1992 | 10/29/1992 | $0 | $0 | $0 | - | ||
9. | 01004 | Serious | 19100307 B | 10/22/1992 | 02/01/1993 | $750 | $750 | $0 | P - Petition to Mod Abatement | ||
10. | 02001A | Other | 19100134 B01 | 10/22/1992 | 11/24/1992 | $0 | $0 | $0 | - | ||
11. | 02001B | Other | 19101200 E01 | 10/22/1992 | 11/24/1992 | $0 | $0 | $0 | - |
Investigation Summary
Employees #1 through #3 were transferring a truckload of oats to a receiving pit inside an enclosed driveway portion of a wooden country elevator. The doorways were open at both ends of the driveway. The facility was equipped with two interior bucket elevator legs. The north leg was being used to lift the oats from the boot pit to a storage bin. At the same time, the south leg was being used to transfer wheat from a storage bin to an outdoor grain dryer. An unknown ignition source within the south bucket elevator started a grain dust explosion. The flame propagated through the return leg of the south elevator and exited through an inspection door near the receiving floor. The suspended dust in the receiving area ignited. Employee #1 was killed. Employees #2 and #3 were hospitalized.
Keywords: BURN, EXPLOSION, COMBUSTIBLE DUST, GRAIN ELEVATOR, GRAIN DUST
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 107114456 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
2 | 107114456 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
3 | 107114456 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |