Inspection Detail
Inspection: 107026312 - T.M.K. Company Dba Terry Crofts Painting Service
Inspection Information - Office: Boise Area Office
Site Address:
T.M.K. Company Dba Terry Crofts Painting Service
3009 South Whitepost Way
Eagle, ID 83616
Mailing Address:
5929 View Drive, Meridian, ID 83642
Union Status: NonUnion
SIC:1721
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 05/18/1989
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/17/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360392369 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 7 | 7 | ||||
| Current Violations | 7 | 7 | ||||
| Initial Penalty | $4,840 | $0 | $0 | $0 | $0 | $4,840 |
| Current Penalty | $2,420 | $0 | $0 | $0 | $0 | $2,420 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 09/14/1989 | 10/05/1989 | $320 | $640 | $0 | 10/05/1989 | R - Review Commission | |
| 2. | 01002 | Serious | 19260021 B02 | 09/14/1989 | 10/05/1989 | $500 | $1,000 | $0 | R - Review Commission | ||
| 3. | 01003 | Serious | 19260059 E01 | 09/14/1989 | 10/05/1989 | $320 | $640 | $0 | R - Review Commission | ||
| 4. | 01004 | Serious | 19260059 G01 | 09/14/1989 | 10/05/1989 | $320 | $640 | $0 | R - Review Commission | ||
| 5. | 01005 | Serious | 19260059 H | 09/14/1989 | 10/05/1989 | $320 | $640 | $0 | R - Review Commission | ||
| 6. | 01006 | Serious | 19260151 A03 | 09/14/1989 | 10/04/1989 | $320 | $640 | $0 | 10/05/1989 | R - Review Commission | |
| 7. | 01007 | Serious | 19260152 F03 | 09/14/1989 | 11/02/1989 | $320 | $640 | $0 | 10/05/1989 | R - Review Commission |
Investigation Summary
ON MAY 16, 1989, EMPLOYEE #1 WAS SPRAY PAINTING A SEALED-OFF ROOM IN A HOUSE. THE WINDOWS AND DOORS WERE ALL CLOSED AND THE ROOM WAS SEPARATED FROM THE REST OF THE HOUSE BY A VISQUEEN SHEET. EMPLOYEES #2 AND #3 WERE WORKING IN AN ADJACENT ROOM. A SPARK (SOURCE UNKNOWN) IGNITED THE PAINT FUMES, WHICH HAD SPREAD THROUGHOUT THE EAST END OF THE HOUSE. EMPLOYEE #1 WAS SEVERELY BURNED AND DIED AT THE SCENE. THE TWO OTHER EMPLOYEES WERE SERIOUSLY BURNED AND TRANSPORTED TO A BURN CENTER. EMPLOYEE #2 DIED AT THE BURN CENTER. EMPLOYEE #3 SURVIVED AND IS BEING TREATMENT FOR THE BURNS HE SUSTAINED. THE COMPANY WAS ISSUED CITATIONS FOR THE LACK OF A HAZARD COMMUNICATION PROGRAM, FAILURE TO ELIMINATE IGNITION SOURCES, AND FAILURE TO PROVIDE ADEQUATE VENTILATION.
Keywords: BURN, VENTILATION, FLAMMABLE VAPORS, FIRE, PAINT, EXPLOSION, PAINTER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107026312 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 107026312 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 3 | 107026312 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |