Inspection Detail
Inspection: 107007684 - Charles Lehman Harris
Inspection Information - Office: Mobile Area Office
Site Address:
Charles Lehman Harris
County Road #26, Judge Estates
Hope Hull, AL 36043
Mailing Address:
Rt. 5, Box 500, Wetumpka, AL 36092
Union Status: NonUnion
SIC:2411
NAICS: 0
Inspection Type: Unprog Rel
Scope: No Insp/Other
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/25/1991
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/10/1991
Investigation Summary
AN EMPLOYEE OF A LOGGING COMPANY WAS UNTANGLING THE REAR, STEEL TIE-DOWN CABLE ON HIS 18-WHEEL TRUCK THAT WAS LOADED WITH LOGS. HE WAS GOING TO THROW THE CABLE OVER THE LOAD TO THE OTHER SIDE OF THE TRUCK IN ORDER TO SECURE THE LOGS. A COWORKER WENT TO THE FRONT TIE-DOWN CABLE TO ASSIST THE FIRST EMPLOYEE. THE COWORKER THREW THE FRONT CABLE OVER THE LOGS, AND IT CONTACTED AN OVERHEAD POWER LINE. THE FIRST EMPLOYEE, WHO WAS STILL HOLDING THE REAR CABLE, WAS ELECTROCUTED.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, WIRE ROPE, ELECTROCUTED, E GI IA, TRUCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107007684 | Occupation Not Listed |
Translate