Inspection Detail
Inspection: 106954738 - Southwestern Bell
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Southwestern Bell
117th Ave. & 186th St.
Miami, FL 33177
Mailing Address:
1801 Kelly St., Dallas, TX 75215
Union Status: NonUnion
SIC:4813
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/02/1992
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/04/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361984404 |
Investigation Summary
A TELEPHONE LINE WORKER WAS WORKING FROM AN AERIAL LIFT BUCKET, TIGHTENING BOLTS ON A CROSSARM BRACE WITH A NON-DOUBLE-INSULATED ELECTRIC IMPACT WRENCH. THE TOOL DEVELOPED A GROUND FAULT, AND THE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTING THE CIRCUIT DID NOT TRIP. THE EMPLOYEE WAS ELECTROCUTED.
Keywords: ELECTRICAL, TELECOM WORK, E TC, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELEC PORT TOOL--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 106954738 | Fatality | Electric Shock | Telephone line installers and repairers |