Inspection Detail
Inspection: 106900855 - Hardwood Floors By Steven Labeau
Inspection Information - Office: Syracuse Area Office
Site Address:
Hardwood Floors By Steven Labeau
1817 Burnet Ave
Syracuse, NY 13206
Mailing Address:
4918 Memory Lane, Manlius, NY 13104
Union Status: NonUnion
SIC:1752
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/30/1998
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 12/29/1998
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100880426 |
Investigation Summary
Employee #1, the sole proprietor of a hardwood flooring company, was contracted to refinish the floors in a second-floor apartment that was being rehabilitated. The prior tenant's animals had left urine stains on the hardwood floors, and he power-sanded all the floors before applying a lacquer finish to seal them. No ventilation was provided and the pilot light of a newly installed gas oven/range ignited the flammable vapors. Employee #1 sustained severe burns and was transported to a local burn center, where he died several days later. The MSDS (Material Safety Data Sheet) for the lacquer finish listed it as a Class IB flammable liquid.
Keywords: BURN, PILOT LIGHT, VENTILATION, FLAMMABLE LIQUID, FLAMMABLE VAPORS, LACQUER, WORK RULES, FIRE, CONSTRUCTION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 106900855 | Fatality | Burn/Scald(Heat) | Occupation not reported |