Inspection Detail
Inspection: 106858343 - Austin Industrial, Inc
Inspection Information - Office: Houston North Area Office
Site Address:
Austin Industrial, Inc
Equistar, Channelview Complex
Channelview,, TX 77530
Mailing Address:
P.O. Box 777, Channelview, TX 77530
Union Status: NonUnion
SIC:1629
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/07/1988
Emphasis:
Case Closed: 02/09/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360693030 |
Investigation Summary
On November 4, 1988, three employees suffered burns from a spray of hot chemicals while dismantling and replacing parts of an evaporator. The chemicals sprayed the employees when one employee removed the lid. The chemicals entered the evaporator by traveling through the lubrication line.
Keywords: BURN, CHEMICAL BURN
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 106858343 | Occupation Not Listed |