Powered by GoogleTranslate

Inspection Detail

Inspection: 106766363 - Tracey Electronics Incorporated

Inspection Information - Office: Region 09; San Francisco

 

Inspection Nr: 106766363
Report ID: 0933300
Date Opened: 04/18/1988

Site Address:
Tracey Electronics Incorporated
1117 West Isabel Street
Burbank, CA 91506

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3479

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/25/1988

Emphasis:

Case Closed: 10/26/1988


Related Activity
Type Activity Nr Safety Health
Accident 360363584
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 2 8
Current Violations 5 2 7
Initial Penalty $1,360 $0 $0 $0 $0 $1,360
Current Penalty $1,080 $0 $0 $0 $0 $1,080
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 E09 I 06/08/1988 07/08/1988 $240 $240 $0 -  
2. 01002 Serious 19100120 L02 I 06/08/1988 07/08/1988 $280 $280 $0 -  
3. 01003 Serious 19101200 H02 II 06/08/1988 06/11/1988 $200 $200 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19101200 H02 III 06/08/1988 06/11/1988 $200 $280 $0 I - Informal Settlement  
5. 02001 Other 19101200 E01 II 06/08/1988 08/30/1988 $0 $0 $0 P - Petition to Mod Abatement  
6. 02002 Other 19101200 E01 III 06/08/1988 08/30/1988 $0 $0 $0 P - Petition to Mod Abatement  
7. 03001 Serious 5A0001 06/15/1988 06/18/1988 $160 $160 $0 -  
8. 03002 Serious 5A0001 06/15/1988 06/18/1988 $200 $200 $0 -  

Investigation Summary

Investigation Nr: 750943
Event: 04/18/1988
Sixteen employees exposed to chlorine gas

Employees #1 through #16 of Burman Metal Finishing were exposed to chlorine that was released next door at Tracey Electronics (inspection #106766363). Chlorine had been released from a tank containing a cupric chloride solution through which copper parts were passed for etching. The solution was out of balance and chlorine was emitted. The alarm to warn of this condition was not working, and the chlorine escaped through the stack and was carried to Burman Metal Finishing (inspection #106766371). Employees #1 through #16 were sent to the hospital after breathing the gas, treated for respiratory irritation, and then released.

Keywords: WORK RULES, ALARM, INHALATION, CHLORINE, ACCIDENTAL DISCHARGE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106766363 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close