Powered by GoogleTranslate

Inspection Detail

Inspection: 106626013 - Gilmore'S Roustabout Service

Inspection Information - Office: Wichita Area Office

 

Inspection Nr: 106626013
Report ID: 0729700
Date Opened: 07/27/1993

Site Address:
Gilmore'S Roustabout Service
4-1/2 Mi N. Of
Plains, KS 67869

Mailing Address:
1910 W. Third St., Liberal, KS 67905

Union Status: NonUnion

SIC:1381

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/19/1993

Emphasis:

Case Closed: 01/31/1994


Related Activity
Type Activity Nr Safety Health
Accident 360425847
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $3,600 $0 $0 $0 $0 $3,600
Current Penalty $3,600 $0 $0 $0 $0 $3,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100151 B 11/02/1993 12/06/1993 $450 $450 $0 -  
2. 01002 Serious 19100332 B01 11/02/1993 12/06/1993 $750 $750 $0 -  
3. 01003 Serious 19100333 C03 11/02/1993 12/06/1993 $750 $750 $0 -  
4. 01004 Serious 19100333 C03 IIIA 11/02/1993 12/06/1993 $750 $750 $0 -  
5. 01005A Serious 19101200 E01 11/02/1993 12/06/1993 $450 $450 $0 -  
6. 01005B Serious 19101200 G08 11/02/1993 12/06/1993 $0 $0 $0 -  
7. 01006 Serious 19101200 H 11/02/1993 12/06/1993 $450 $450 $0 -  
8. 02001 Other 19040002 A 11/02/1993 12/06/1993 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14423115
Event: 07/21/1993
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

One employee working for an oil well drilling firm and three employees working for a contractor were working at a well site. One of the contractor's employees was driving a winch truck; the other two were spotters in the field. The contractors' employees were moving a pumping unit beneath an overhead power line. One of the contractor's employees stated to the employee of the drilling company (employee #1) that the pump would not clear the power line. Employee #1 climbed onto an I-beam, said that the line had to have been deenergized, and ordered the work to proceed. He touched the first phase conductor and nothing happened. He moved that conductor to the other side of the horse head on the pump. As the other employees moved the unit, employee #1 placed the neutral conductor over the horse head. Employee #1, the I-beam, and the horse head were between the two phase conductors at that time. As employee #1 approached the second phase conductor, he moved to the side of the I-beam and was within 150 millimeters (6 inches) of the second phase conductor. When he reached over the beam to get a better grip, he contacted the second phase conductor, which was energized, and was electrocuted.

Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, OIL WELL DRILLING, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106626013 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close