Powered by GoogleTranslate

Inspection Detail

Inspection: 106603962 - Warren Sign Company, Inc.

Inspection Information - Office: Fort Worth Area Office

 

Inspection Nr: 106603962
Report ID: 0636900
Date Opened: 07/03/1990

Site Address:
Warren Sign Company, Inc.
1207 Main Street
Gainesville, TX 76528

Mailing Address:
P. O. Box 23087, Waco, TX 76702

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/20/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/27/1991


Related Activity
Type Activity Nr Safety Health
Accident 360694236
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $1,860 $0 $0 $60 $0 $1,920
Current Penalty $1,440 $0 $0 $0 $0 $1,440
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260020 B04 08/13/1990 09/14/1990 $420 $420 $0 -  
2. 01001B Serious 19260021 B02 08/13/1990 09/14/1990 $0 $0 $0 -  
3. 01003 Serious 19260100 A 08/13/1990 08/21/1990 $180 $180 $0 08/28/1990 J - ALJ Decision  
4. 01005 Serious 19260404 B01 II 08/13/1990 08/21/1990 $210 $420 $0 08/28/1990 J - ALJ Decision  
5. 01006A Serious 19260404 F03 IB 08/13/1990 08/21/1990 $420 $420 $0 08/28/1990 J - ALJ Decision  
6. 01006B Serious 19260404 F06 08/13/1990 08/21/1990 $0 $0 $0 08/28/1990 J - ALJ Decision  
7. 01006C Serious 19260405 G01 II 08/13/1990 08/21/1990 $0 $0 $0 -  
8. 01008A Serious 19260417 A 08/13/1990 08/21/1990 $210 $420 $0 08/28/1990 J - ALJ Decision  
9. 01008B Serious 19260417 B 08/13/1990 08/21/1990 $0 $0 $0 08/28/1990 J - ALJ Decision  
10. 02001 Other 19040002 A 08/13/1990 08/21/1990 $0 $60 $0 08/28/1990 J - ALJ Decision  

Investigation Summary

Investigation Nr: 565671
Event: 07/02/1990
ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC SIGN

TWO EMPLOYEES OF A SIGN COMPANY WERE ASSIGNED TO REPAIR THE LIGHTING ON A SIGN FOR A FOOD STORE. THE POLE-MOUNTED SIGN WAS LOCATED ABOUT 30 FEET ABOVE THE GROUND. THE EMPLOYEES TRIED TO ENERGIZE THE SIGN FROM THE PANELBOARD INSIDE THE STORE. THIS EFFORT FAILED TO LIGHT THE SIGN, SO THE EMPLOYEES RIGGED THE GENERATOR ON A SKYHOOK AERIAL LIFT TO SUPPLY ELECTRIC POWER. ONE OF THE EMPLOYEES WAS IN THE AERIAL LADDER BUCKET, WHILE THE OTHER WAS BELOW. WHEN THE GENERATOR WAS ENERGIZED, THE SIGN LIT. THE EMPLOYEE ON THE GROUND WENT UP TO JOIN HIS COWORKER IN THE BUCKET. AS HE CLIMBED INTO THE BUCKET, THE EMPLOYEE GRABBED THE SIGN TO STEADY HIMSELF (WITH ONE HAND ON THE BUCKET AND ONE HAND ON THE SIGN). HE WAS ELECTROCUTED BY AN APPARENT GROUND FAULT IN THE SIGN.

Keywords: ELECTRICAL, ELECTRIC SIGN, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, AERIAL LIFT, ELECTRIC GENERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106603962 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close