Inspection Information - Office: Fort Worth Area Office

 

Inspection Nr: 106600893
Report ID: 0636900
Date Opened: 01/23/1990

Site Address:
Plum-Rite Plumbing Co.
3108 Meadowbrook Drive
Fort Worth, TX 76103

Mailing Address:
3585 Paramount Street, Fort Worth, TX 76117

Union Status: NonUnion

SIC:1711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/06/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/05/1991


Related Activity
Type Activity Nr Safety Health
Accident 360557342
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $240 $0 $0 $0 $0 $240
Current Penalty $120 $0 $0 $0 $0 $120
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260404 B01 I 03/02/1990 03/05/1990 $120 $240 $0 I - Informal Settlement  
2. 02001 Other 19040008 03/02/1990 03/05/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 567008
Event: 10/13/1989
ELECTRIC SHOCK - GROUND FAULT IN CABLE

AN EMPLOYEE HAD BEEN HIRED ON A TEMPORARY BASIS TO HELP A PLUMBER WITH TWO HOUSES. HE PERFORMED LABOR-ORIENTED TASKS, SUCH AS CUTTING PIPE AND DIGGING DITCHES. ON HIS SECOND DAY, THE PLUMBER AND HIS HELPER WERE WORKING UNDER ONE OF THE HOUSES. THE PLUMBER WENT TO HIS TRUCK; AND, WHEN HE RETURNED ABOUT A MINUTE LATER, HE FOUND HIS HELPER UNCONSCIOUS. HE COULD NOT REVIVE THE INJURED EMPLOYEE, WHO WAS PRONOUNCED DEAD 2 HOURS LATER. THE MEDICAL EXAMINER FOUND EVIDENCE OF ELECTRIC SHOCK AND RULED THE DEATH AN ELECTROCUTION. THE ONLY ELECTRIC EQUIPMENT IN USE HAD BEEN A UTILITY LAMP AND A 2-CONDUCTOR EXTENSION CORD SET. THE MEDIUM-DUTY TYPE SJT EXTENSION CORD SET HAD A REPLACEMENT CORD CONNECTOR, BUT WAS APPARENTLY IN GOOD CONDITION. THE PLUMBER HAD NOTICED A 240-VOLT LINE IN FLEXIBLE METAL CONDUIT AND A 120-VOLT JUNCTION BOX. HE HAD TOLD HIS HELPER TO AVOID THEM. OSHA WAS NOT NOTIFIED UNTIL 6 WEEKS AFTER THE ACCIDENT, AND BY THAT TIME THE SITE HAD BEEN ALTERED. HOWEVER, THE HOMEOWNER'S INSURANCE COMPANY HAD AN ELECTRICIAN INSPECT THE PROPERTY. THE ELECTRICIAN HAD FOUND AN ARMORED CABLE (SUPPLYING A FLOODLIGHT) IN THE ATTIC. THE CABLE HAD FAULTED TO AN OLD FURNACE VENT PIPE. THE ENERGIZED VENT PIPE EXTENDED DOWN THROUGH THE HOUSE TO THE CRAWL SPACE WHERE THE TWO EMPLOYEES HAD BEEN WORKING. THE ELECTRICIAN IDENTIFIED THIS VENT PIPE AS THE ONLY UNINSULATED SOURCE OF ELECTRICAL ENERGY. HE THEORIZED THAT THE HELPER HAD TOUCHED IT EITHER DIRECTLY OR THROUGH A PIECE OF COPPER PIPE HE WAS CLUTCHING WHEN HE WAS FOUND. THE ARMORED CABLE, WHICH HAD HAD A HOLE BURNED THROUGH ITS ARMORED SHEATH AND INNER INSULATION, WAS REPLACED.

Keywords: DUCT, ELECTRICAL, ELECTRIC CABLE, E GI VII, ELECTROCUTED, GROUND FAULT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106600893 Fatality Electric Shock Helpers, construction trades
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.