Inspection Detail
Inspection: 106443054 - Mates Georgia National Guard
Inspection Information - Office: Savannah Area Office
Site Address:
Mates Georgia National Guard
Building 10531, Troupe Avenue
Ft. Stewart, GA 31314
Mailing Address:
P.O. Box 437, Hinesville, GA 31314
Union Status: Union
SIC:9711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership:
Safety/Health: Safety
Close Conference: 11/08/1991
Emphasis:
Case Closed: 02/18/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360449268 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 13 | 13 | ||||
| Current Violations | 13 | 13 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100252 A02 XIVA | 12/06/1991 | 12/09/1991 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Serious | 19100252 A03 I | 12/06/1991 | 12/09/1991 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Serious | 19100252 B03 | 12/06/1991 | 12/09/1991 | $0 | $0 | $0 | - | ||
| 4. | 01004 | Serious | 19101200 F05 I | 12/06/1991 | 12/09/1991 | $0 | $0 | $0 | - | ||
| 5. | 01006 | Serious | 19100252 A03 I | 01/24/1992 | 01/26/1992 | $0 | $0 | $0 | - | ||
| 6. | 02001 | Serious | 19100252 A02 XIIIC | 01/24/1992 | 01/27/1992 | $0 | $0 | $0 | - | ||
| 7. | 02002 | Serious | 19100252 A02 XIVA | 01/24/1992 | 01/26/1992 | $0 | $0 | $0 | - | ||
| 8. | 02003 | Serious | 19100252 A02 XIVB | 01/24/1992 | 01/27/1992 | $0 | $0 | $0 | - | ||
| 9. | 02004 | Serious | 19100252 A02 XIVC | 01/24/1992 | 01/27/1992 | $0 | $0 | $0 | - | ||
| 10. | 02005 | Serious | 19100252 A02 XIVC | 01/24/1992 | 01/27/1992 | $0 | $0 | $0 | - | ||
| 11. | 02007 | Serious | 19100252 A03 II | 01/24/1992 | 01/26/1992 | $0 | $0 | $0 | - | ||
| 12. | 02008 | Serious | 19100252 B03 | 01/24/1992 | 01/27/1992 | $0 | $0 | $0 | - | ||
| 13. | 02009 | Serious | 19101200 F05 I | 01/24/1992 | 01/26/1992 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1, an Army Ready Reserve National Guard military technician, was welding a cracked fuel cell on an M60A3 tank. The fuel cell had not been cleaned and purged before the welding operation began. Apparently the diesel fuel was mixed with MOGAS, unleaded automotive gasoline, and a fire ensued. Employee #1 was burned on 30 percent of his body. He died 17 days later. Information obtained indicates that the diesel fuel was emptied from the fuel cell into a TPU that contained MOGAS, and then put back into the fuel cell.
Keywords: BURN, DIESEL FUEL TANK, WORK RULES, FIRE, WELDING, GASOLINE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 106443054 | Fatality | Burn/Scald(Heat) | Occupation not reported |
Translate