Powered by GoogleTranslate

Inspection Detail

Inspection: 106417231 - Boehm Well Service, Inc.

Inspection Information - Office: Denver Area Office

 

Inspection Nr: 106417231
Report ID: 0830500
Date Opened: 09/07/1993

Site Address:
Boehm Well Service, Inc.
N E N W, Sec. 11, Township 4 North Range 65 West
Evans, CO 80620

Mailing Address:
P.O. Box 1823, Grand Junction, CO 81502

Union Status: NonUnion

SIC:1389

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/22/1993

Emphasis:

Case Closed: 12/29/1993


Related Activity
Type Activity Nr Safety Health
Inspection 106417223
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $2,250 $0 $0 $0 $0 $2,250
Current Penalty $1,575 $0 $0 $0 $0 $1,575
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 B06 12/03/1993 12/06/1993 $1,050 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19101030 C01 I 12/03/1993 01/03/1994 $525 $750 $0 I - Informal Settlement  
3. 02001A Other 19101200 E01 12/03/1993 01/03/1994 $0 $0 $0 -  
4. 02001B Other 19101200 E01 I 12/03/1993 01/03/1994 $0 $0 $0 -  
5. 02001C Other 19101200 G01 12/03/1993 01/03/1994 $0 $0 $0 -  
6. 02001D Other 19101200 H 12/03/1993 01/03/1994 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 522177
Event: 09/07/1993
Employees suffer injuries in oil/gas well explosion

At approximately 6:20 p.m. on September 3, 1993, Employees #1 through #5 were working together to "kill" an oil/gas well so that they could repair a hole in the casing. To release pressure from the wewll head during the circulating process, natural gas was being vented out of the top of the flow back tank approximately 30 feet from the diesel engines mounted on the pump truck. When the vented natural gas entered the area where the diesel engines were running, it ignited. A flash fire resulted. Employees #1, #2, and #3 were hospitalized while Employees #4 and #5 were treated and released.

Keywords: VENTING, WORK RULES, ENGINE, GAS WELL DRILLING, REPAIR, FIRE, OIL WELL DRILLING, NATURAL GAS, WELLHEAD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106417231 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close