Inspection Detail
Inspection: 106233026 - Matthews, Inc.
Inspection Information - Office: Birmingham Area Office
Site Address:
Matthews, Inc.
Southeast Of Tuscaloosa
Tuscaloosa, AL 35401
Mailing Address:
P. O. Box 1050, Priston, OK 74010
Union Status: NonUnion
SIC:1311
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 11/26/1990
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/15/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360142475 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 4 | 5 | |||
| Current Violations | 1 | 4 | 5 | |||
| Initial Penalty | $1,000 | $0 | $0 | $0 | $0 | $1,000 |
| Current Penalty | $1,000 | $0 | $0 | $0 | $0 | $1,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 01/29/1991 | 02/04/1991 | $1,000 | $1,000 | $0 | - | ||
| 2. | 02001 | Other | 19101200 E01 | 01/29/1991 | 03/04/1991 | $0 | $0 | $0 | - | ||
| 3. | 02002 | Other | 19101200 E01 I | 01/29/1991 | 03/04/1991 | $0 | $0 | $0 | - | ||
| 4. | 02003 | Other | 19101200 G08 | 01/29/1991 | 03/04/1991 | $0 | $0 | $0 | - | ||
| 5. | 02004 | Other | 19101200 H | 01/29/1991 | 03/04/1991 | $0 | $0 | $0 | - |
Investigation Summary
Three employees were setting up a well service vehicle over a gas well so that they could remove the well pump and replace it with a new one. During this operation, a cable contacted a 7600-volt, three-phase overhead power line. The employees were in contact with the cable and received electric shocks. One of the employees was electrocuted. One of the other two employees was hospitalized for his injury. (Only the hospitalized injury was listed on the original form. The fatality and the other electric shock injury were not listed.)
Keywords: WELL SERVICE RIG, OVERHEAD POWER LINE, ELECTRICAL, WIRE ROPE, ELECTROCUTED, E GI IA, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 106233026 | Hospitalized injury | Electric Shock | Occupation not reported |