Powered by GoogleTranslate

Inspection Detail

Inspection: 106210370 - Wingate Electric Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 106210370
Report ID: 0420600
Date Opened: 10/10/1990

Site Address:
Wingate Electric Inc.
312 N. Buena-Vista Drive
Lake Alfred, FL 33850

Mailing Address:
1411 42nd Street N.W., Winter Haven, FL 33880

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/11/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/31/1990


Related Activity
Type Activity Nr Safety Health
Accident 360728828
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $300 $0 $0 $0 $0 $300
Current Penalty $300 $0 $0 $0 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260059 E01 10/30/1990 11/07/1990 $150 $150 $0 -  
2. 01002 Serious 19260059 G01 10/29/1990 11/07/1990 $150 $150 $0 -  

Investigation Summary

Investigation Nr: 14345607
Event: 10/01/1990
Employee crushed to death when caught in capstan

At approximately 8:00 a.m. on or about October 1, 1990, Employee #1 was performing his normal task of mixing fertilizers and sending them to special bins. He wrapped the manila rope around the capstan twice and started to pull the rope tighter to engage the conveyor system when he was evidently pulled by the capstan. His left hand and arm were caught and his arm wrapped around the capstan. He tried to extricate himself with his right hand, but it became caught in the rope and his thumb and right index finger were nearly severed. Employee #1 could not get to the switch to turn the machine off because he was out of position. The stop switch is approximately 52 inches from the capstan and the operator must stand in front of the capstan and switch, not on the side. Employee #1 was taken to the hospital. He died 3 days later.

Keywords: FERTILIZER MIXING, LACERATION, HAND, ROPE, FINGER, CAUGHT BY, CONSTRUCTION, ARM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106210370 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.