Inspection Detail
Inspection: 106144728 - Perini-Power Joint Venture
Inspection Information - Office: Chicago North Area Office
Site Address:
Perini-Power Joint Venture
195 N. Harbor Drive
Chicago, IL 60601
Mailing Address:
11 South Lasalle )Treet, Chicago, IL 60603
Union Status: Union
SIC:1542
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/14/1991
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 05/15/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360360127 |
Investigation Summary
At approximately 12:30 p.m. on April 20, 1991, Employee #1 was getting onto the platform of a two-point suspension scaffold through a window at the 48th floor. He was preparing to finish caulking windows that were started earlier that day. Because the window hinged at the bottom and swiveled open, the employee had to access the window feet-first with his back to the scaffold and then step onto the platform. No tie-off to independent safety lines was in use. Employee #1 apparently missed the platform and fell through a gap between the scaffold and the building. He fell 40 floors to his death.
Keywords: TIE-OFF, LIFELINE, FALL, FALL PROTECTION, SCAFFOLD, WORK RULES, ELEVATED WORK PLAT, CONSTRUCTION, UNSTABLE POSITION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 106144728 | Occupation Not Listed |