Inspection Detail
Inspection: 106051212 - K-Tek Corporation
Inspection Information - Office: Eau Claire Area Office
Site Address:
K-Tek Corporation
750 Vandeberg Drive
Baldwin, WI 54002
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3469
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/25/2002
Emphasis: S:Amputations
Case Closed: 09/06/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 200340438 | Yes |
Investigation Summary
On July 23, 2002, Employee #1 was operating an Auto-Cert Pen Setter when she inadvertently depressed the pedal switch, causing the machine to cycle. Employee #1's right index finger was crushed and amputated while it was in the point of operation. The safety switch did not detect Employee #1's finger in the point of operation. It is believed that hydraulic fluid leaked undetected from the ram cylinder into the tooling where the safety switch was located, causing it to malfunction. Employee #1 was taken to the hospital and treated for her injuries.
Keywords: CYLINDER, INADEQUATE MAINT, FINGER, EQUIPMENT OPERATOR, HYDRAULIC FLUID, CRUSHED, POINT OF OPERATION, FOOT-POWERED PRESS, ELECTRICAL FAULT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 106051212 | Non Hospitalized injury | Amputation | Punching and stamping press machine operators |