Powered by GoogleTranslate

Inspection Detail

Inspection: 105761852 - Bill'S Classic Cars

Inspection Information - Office: Va-E-Roanoke (Regional Office) -Safety 0355118

 

Inspection Nr: 105761852
Report ID: 0355118
Date Opened: 02/09/1990

Site Address:
Bill'S Classic Cars
385 Calhoun St.
Wytheville, VA 24382

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7532

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/27/1990

Emphasis:

Case Closed: 05/16/1990


Related Activity
Type Activity Nr Safety Health
Accident 360784789
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $750 $0 $0 $0 $0 $750
Current Penalty $750 $0 $0 $0 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100107 C02 04/13/1990 04/17/1990 $350 $350 $0 -  
2. 01001B Serious 19100107 D02 04/13/1990 04/17/1990 $0 $0 $0 I - Informal Settlement Citation has been deleted.
3. 01001C Serious 19100107 G02 04/13/1990 04/17/1990 $0 $0 $0 -  
4. 01002A Serious 19101200 E01 04/13/1990 05/16/1990 $400 $400 $0 -  
5. 01002B Serious 19101200 F04 I 04/13/1990 05/16/1990 $0 $0 $0 -  
6. 01002C Serious 19101200 G01 04/13/1990 05/16/1990 $0 $0 $0 I - Informal Settlement Citation has been deleted.
7. 01002D Serious 19101200 H 04/13/1990 05/16/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 953059
Event: 02/06/1990
Employee burned by ignited paint vapors

At 11:00 a.m on February 6, 1990, Employee #1 was inside a Binks spray booth, which is used to paint vehicles, cleaning paint residue off its sides with water. He had finished painting a vehicle approximately 2 hours earlier. Meanwhile, flammable vapors had accumulated in the spray booth and shop area of the facility. The exhaust fan in the spray booth was off and the bay doors of the shop were closed. A gas-powered water heater, located within 20 ft of the spray booth, apparently ignited the vapors. The fire followed the vapor path back to the spray booth where Employee # 1 was located. He was engulfed by the fire and suffered burns over 80 percent of his body, for which he was hospitalized.

Keywords: BURN, VENTILATION, FLAMMABLE VAPORS, WORK RULES, CLEANING, FIRE, PAINT, SPRAY BOOTH

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105761852 Hospitalized injury Burn/Scald(Heat) Automobile body and related repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close