Powered by GoogleTranslate

Inspection Detail

Inspection: 105711667 - Carl E. Smith, Inc.

Inspection Information - Office: Va-E-Manassas (Regional Office)- Safety 0355114

 

Inspection Nr: 105711667
Report ID: 0355114
Date Opened: 06/08/1988

Site Address:
Carl E. Smith, Inc.
Parc City Centre & Leesburg Pike
Sterling, VA 22170

Mailing Address:
P. O. Box 4, Sandyville, WV 25275

Union Status: Union

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/12/1988

Planning Guide: Safety-Construction

Emphasis: N:Trench

Case Closed: 10/31/1989


Related Activity
Type Activity Nr Safety Health
Accident 360606651
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $640 $0 $0 $0 $0 $640
Current Penalty $500 $0 $0 $0 $0 $500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260651 I01 07/25/1988 07/29/1988 $500 $640 $0 08/08/1988 1 - State Lower Court  
2. 01001B Serious 19260651 P 07/25/1988 07/29/1988 $0 $0 $0 08/08/1988 1 - State Lower Court Citation has been deleted.
3. 01001C Serious 19260652 B 07/25/1988 07/29/1988 $0 $0 $0 08/08/1988 1 - State Lower Court  
4. 01001D Serious 19260652 E 07/25/1988 07/29/1988 $0 $0 $0 08/08/1988 1 - State Lower Court Citation has been deleted.

Investigation Summary

Investigation Nr: 893115
Event: 06/08/1988
Employees injured during trench cave-in

At 1:39 p.m. on June 8, 1988, Employees #1 through #3 were installing a 24 in. steel gas main in a trench that was approximately 125 ft long by 13 ft wide at the top and 5 ft wide at the bottom by approximately 14 ft deep. The area they were working in was shored by 2 ft 3/4 in., 8 ft by 12 ft steel plates. Two in. steel pipe was used as cross braces. The employees were going to weld two sections of pipe together. The ends did not match up so one section had to be marked and cut. This operation was performed inside the shored area. The retaining ring on the east pipe section had to be loosened and pushed back from the end of the pipe so that about 2 ft could be cut off. This ring was pushed back along the pipe by Employees #1 and #3, who, in so doing, stepped outside the shoring just as a section of the north side of the trench caved in. Employee #1 suffered a ruptured spleen, intestinal bleeding, and various contusions and abrasions. Employee #2 suffered a bruised right leg and Employee #3 suffered a fractured pelvis and various leg contusions. The area that caved in was where an inactive telephone service had been installed and intersected the gas main trench. Causes of this accident included working in a previously backfilled area, and lack of shoring in that area.

Keywords: FRACTURE, INSTALLING, WORK RULES, CONSTRUCTION, TRENCH, SHORING, UNSTABLE SOIL, SLOPING, CAVE-IN, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105711667 Non Hospitalized injury Bruise/Contus/Abras Welders and cutters
2 105711667 Hospitalized injury Fracture Helpers, construction trades
3 105711667 Hospitalized injury Other Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close