Inspection Detail
Inspection: 105702898 - Hawkins & Cox, Inc.
Inspection Information - Office: Va-E-Roanoke (Regional Office) -Safety 0355118
Site Address:
Hawkins & Cox, Inc.
Lake Drive Plaza, Rt. 24
Vinton, VA 24179
Mailing Address:
1719 Norfolk Ave., S.E., Roanoke, VA 24012
Union Status: NonUnion
SIC:1791
NAICS: 0
Inspection Type: Planned
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/13/1988
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/30/1988
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19260550 A12 | 07/26/1988 | 07/30/1988 | $0 | $0 | $0 | - |
Investigation Summary
An ironworker was sitting on a beam about 24.4 meters (80 feet) above the ground, installing 3.3-meter-long (10.9-foot-long), 13-millimeter-diameter (0.5-inch-diameter) sag rods. A 19.9-kilovolt overhead power line was located about 2.7 meters (9 feet) above him. A sag rod that the employee was installing contacted the power line, and the employee was electrocuted. (He also fell to the ground.)
Keywords: METAL WIRE, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E GI IC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 105702898 | Fatality | Electric Shock | Structural metal workers |