Powered by GoogleTranslate

Inspection Detail

Inspection: 105681159 - Westvaco

Inspection Information - Office: Va-E-Roanoke (Regional Office) -Safety 0355118

 

Inspection Nr: 105681159
Report ID: 0355118
Date Opened: 05/05/1988

Site Address:
Westvaco
104 East Riverside Street
Covington, VA 24426

Mailing Address:
, , 00000

Union Status: Union

SIC:2621

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/30/1988

Emphasis:

Case Closed: 12/29/1988


Related Activity
Type Activity Nr Safety Health
Accident 362311136
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $900 $0 $0 $0 $0 $900
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 510001 A 11/02/1988 11/06/1988 $900 $900 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 899013
Event: 05/04/1988
TEN EMPLOYEES INJURED WHEN EXPOSED TO HYDROGEN SULFIDE GAS

AT 10 A.M. ON MAY 4, 1988, TEN EMPLOYEES WERE HOSPITALIZED AS A RESULT OF HYDROGEN SULFIDE EXPOSURE AT WESTVACO. A FAILURE OF THE #2 STORAGE TANK CAUSED APPROXIMATELY 300,000 GALLONS OF GREEN LIQUOR TO SPILL INTO A RIVER AND STORM DRAINAGE SEWER SYSTEM. THE DRAINAGE SYSTEM IS LOCATED AROUND THE STORAGE TANKS AND CONTINUES TOWARD THE RECOVERY BUILDING. THE PURPOSE OF THIS DRAINAGE SYSTEM IS TO COLLECT RUN-OFF FROM OPERATIONS LOCATED ALONG THE SYSTEM. SOME OF THE OPERATIONS DISCHARGE ACIDS INTO THE DRAINAGE SYSTEM. GREEN LIQUOR WAS SPILLED INTO THE DRAINAGE SYSTEM WHEN THE TANK RUPTURED. THE GREEN LIQUOR COMBINED WITH ACID IN THE DRAINAGE SYSTEM TO FORM HYDROGEN SULFIDE GAS. EMPLOYEES WERE AFFECTED AT VARIOUS LOCATIONS ALONG THE PATH OF THE DRAINAGE SYSTEM TO THE WASTE TREATMENT PLANT.

Keywords: RESPIRATORY, HYDROGEN SULFIDE, INHALATION, STORAGE TANK, RUPTURE, CHEMICAL REACTION, TOXIC FUMES, ACCIDENTAL DISCHARGE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105681159 Hospitalized injury Other Occupation not reported
2 105681159 Hospitalized injury Other Occupation not reported
3 105681159 Hospitalized injury Other Occupation not reported
4 105681159 Hospitalized injury Other Occupation not reported
5 105681159 Hospitalized injury Other Occupation not reported
6 105681159 Hospitalized injury Other Occupation not reported
7 105681159 Hospitalized injury Other Occupation not reported
8 105681159 Hospitalized injury Other Occupation not reported
9 105681159 Hospitalized injury Other Occupation not reported
10 105681159 Hospitalized injury Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.