Inspection Detail
Inspection: 105678312 - Montague-Betts Co., Inc.
Inspection Information - Office: Virginia Central 0355100
Site Address:
Montague-Betts Co., Inc.
300 Rangoon Road
Lynchburg, VA 24506
Mailing Address:
1619 Wythe Road, Lynchburg, VA 24506
Union Status: NonUnion
SIC:3441
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/03/1990
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/29/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360300651 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 3 | 5 | |||
| Current Violations | 2 | 3 | 5 | |||
| Initial Penalty | $1,450 | $0 | $0 | $0 | $0 | $1,450 |
| Current Penalty | $1,450 | $0 | $0 | $0 | $0 | $1,450 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100303 G01 I | 09/12/1990 | 09/20/1990 | $450 | $450 | $0 | - | ||
| 2. | 01002 | Serious | 19100303 G02 II | 09/12/1990 | 09/20/1990 | $1,000 | $1,000 | $0 | - | ||
| 3. | 02001 | Other | 19100147 C04 II | 09/12/1990 | 09/20/1990 | $0 | $0 | $0 | - | ||
| 4. | 02002 | Other | 19100147 C07 IV | 09/12/1990 | 09/20/1990 | $0 | $0 | $0 | - | ||
| 5. | 02003 | Other | 19100303 G01 II | 09/12/1990 | 09/20/1990 | $0 | $0 | $0 | - |
Investigation Summary
A shop worker was informed by a coworker that he was receiving electric shocks from a material scoop. The scoop, which weighed 907 kilograms, had been sitting on two 76-millimeter by 76-millimeter by 914-millimeter wooden blocks for about 24 hours. A metal strap on the scoop had cut into a cable and was touching a conductor inside the cable. This had energized the metal scoop. The shop worker went to the material scoop and put his left hand on the scoop and his right on a grounded welding rod oven. He was electrocuted. (The coworker, who also received an electric shock, was not listed on an injury line on the original form.)
Keywords: E GI V, ELEC INSULATION, ELECTRICAL, ELECTRIC CABLE, ELECTROCUTED, GROUND FAULT, ELECTRIC CONDUCTOR, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 105678312 | Fatality | Electric Shock | Precision grinders, fitters and tool sharpeners |