Inspection Detail
Inspection: 1056650.015 - Magnegas Corporation
Inspection Information - Office: Tampa Area Office
Site Address:
Magnegas Corporation
150 Rainville Rd.
Tarpon Springs, FL 34689
Mailing Address:
150 Rainville Rd., Tarpon Springs, FL 34689
Union Status: NonUnion
SIC:
NAICS: 325120/Industrial Gas Manufacturing
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/14/2015
Emphasis: L:Forklift
Case Closed: 11/17/2015
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 976188 | ||
Inspection | 1065698 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 16 | 5 | 21 | |||
Current Violations | 16 | 5 | 21 | |||
Initial Penalty | $52,045 | $0 | $0 | $0 | $0 | $52,045 |
Current Penalty | $52,045 | $0 | $0 | $0 | $0 | $52,045 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 10/14/2015 | 11/02/2015 | $4,900 | $4,900 | $0 | Z - Issued | ||
2. | 01002 | Serious | 19100132 A | 10/14/2015 | 10/20/2015 | $4,900 | $4,900 | $0 | Z - Issued | ||
3. | 01003 | Serious | 19100157 E02 | 10/14/2015 | $2,380 | $2,380 | $0 | Z - Issued | |||
4. | 01004A | Serious | 19100178 C02 III | 10/14/2015 | 10/20/2015 | $4,900 | $4,900 | $0 | Z - Issued | ||
5. | 01004B | Serious | 19100178 C02 V | 10/14/2015 | 10/20/2015 | $0 | $0 | $0 | Z - Issued | ||
6. | 01005 | Serious | 19100178 L02 III | 10/14/2015 | 10/26/2015 | $2,100 | $2,100 | $0 | Z - Issued | ||
7. | 01006 | Serious | 19100212 A01 | 10/14/2015 | 10/20/2015 | $4,900 | $4,900 | $0 | Z - Issued | ||
8. | 01007 | Serious | 19100212 A03 II | 10/14/2015 | 10/20/2015 | $3,500 | $3,500 | $0 | Z - Issued | ||
9. | 01008 | Serious | 19100212 B | 10/14/2015 | 10/20/2015 | $2,100 | $2,100 | $0 | Z - Issued | ||
10. | 01009 | Serious | 19100242 B | 10/14/2015 | 10/20/2015 | $2,100 | $2,100 | $0 | Z - Issued | ||
11. | 01010 | Serious | 19100243 C01 | 10/14/2015 | $1,785 | $1,785 | $0 | Z - Issued | |||
12. | 01011 | Serious | 19100304 F01 VIII | 10/14/2015 | 10/20/2015 | $2,100 | $2,100 | $0 | Z - Issued | ||
13. | 01012 | Serious | 19100305 B01 II | 10/14/2015 | 10/20/2015 | $2,100 | $2,100 | $0 | Z - Issued | ||
14. | 01013A | Serious | 19100305 G01 IV A | 10/14/2015 | 10/20/2015 | $2,100 | $2,100 | $0 | Z - Issued | ||
15. | 01013B | Serious | 19100305 G01 IV B | 10/14/2015 | 10/20/2015 | $0 | $0 | $0 | Z - Issued | ||
16. | 01013C | Serious | 19100305 G01 IV D | 10/14/2015 | 10/20/2015 | $0 | $0 | $0 | Z - Issued | ||
17. | 01013D | Serious | 19100305 G01 IV E | 10/14/2015 | 10/20/2015 | $0 | $0 | $0 | Z - Issued | ||
18. | 01014 | Serious | 19100305 G02 III | 10/14/2015 | $2,380 | $2,380 | $0 | Z - Issued | |||
19. | 01015A | Serious | 19100307 B | 10/14/2015 | 10/20/2015 | $4,900 | $4,900 | $0 | Z - Issued | ||
20. | 01015B | Serious | 19100307 C | 10/14/2015 | 10/20/2015 | $0 | $0 | $0 | Z - Issued | ||
21. | 01016A | Serious | 19101200 E01 | 10/14/2015 | 10/26/2015 | $4,900 | $4,900 | $0 | Z - Issued | ||
22. | 01016B | Serious | 19101200 H01 | 10/14/2015 | 10/26/2015 | $0 | $0 | $0 | Z - Issued | ||
23. | 02001 | Other | 19100023 D01 | 10/14/2015 | $0 | $0 | $0 | Z - Issued | |||
24. | 02002 | Other | 19100147 F03 I | 10/14/2015 | 10/26/2015 | $0 | $0 | $0 | Z - Issued | ||
25. | 02003 | Other | 19100178 P01 | 10/14/2015 | $0 | $0 | $0 | Z - Issued | |||
26. | 02004 | Other | 19100303 B02 | 10/14/2015 | $0 | $0 | $0 | Z - Issued | |||
27. | 02005 | Other | 19100305 B02 I | 10/14/2015 | 10/20/2015 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At approximately 1:56 p.m. on April 16, 2015, Employee #1 and Employee #2 were draining liquids from compressed gas DOT cylinders containing unspecified compressed gas called Magnegas. The employees had drained the liquid from 10 out of 12 compressed gas cylinders that were filled with Magnegas. The cylinders were part of a twelve-cylinder manifold. Employee #2 was placing the tenth cylinder back into the manifold and Employee #1 was getting the eleventh cylinder ready for draining when it exploded. The cylinders were filled to 1950 psi with Magnegas. The exploding cylinder killed Employee #1 and hospitalized Employee #2, who underwent shrapnel removal surgeries and burn treatment.
Keywords: Compressed Gas, Explosion
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1056650.015 | 29 | M | Fatality | Production helpers | |
2 | 1056650.015 | 42 | M | Hospitalized injury | Production helpers |