Inspection Detail
Inspection: 1056368.015 - Prism Integrated Solutions Usa, Inc.
Inspection Information - Office: Corpus Christi Area Office
Site Address:
Prism Integrated Solutions Usa, Inc.
2045 Les Mauldin Road
Brownsville, TX 78521
Mailing Address:
2045 Les Mauldin Road, Brownsville, TX 78521
Union Status: NonUnion
SIC:
NAICS: 333132/Oil and Gas Field Machinery and Equipment Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/15/2015
Emphasis: L:Gifall
Case Closed: 07/29/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 975682 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
| Current Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100178 L01 I | 09/30/2015 | 10/16/2015 | $7,000 | $7,000 | $0 | Z - Issued | ||
| 2. | 02001 | Other | 19101200 E01 | 09/30/2015 | 10/23/2015 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At approximately 10:00 p.m. on April 14, 2015, Employee #1 was cleaning the floor when he was struck and killed by an unspecified object.
Keywords: Cleaning, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1056368.015 | 40 | M | Fatality |