Powered by GoogleTranslate

Inspection Detail

Inspection: 105606313 - Hoffine Printing Inc

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 105606313
Report ID: 0854910
Date Opened: 10/10/1990

Site Address:
Hoffine Printing Inc
2280 South 600 West
West Valley City, UT 84115

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/10/1990

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/19/1991


Related Activity
Type Activity Nr Safety Health
Accident 360288559
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $720 $0 $0 $0 $0 $720
Current Penalty $720 $0 $0 $150 $0 $870
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 10/26/1990 11/02/1990 $360 $360 $0 -  
2. 01002 Serious 19100212 A03 II 10/26/1990 11/02/1990 $360 $360 $0 A - Amendment  
3. 02001 Other 10200130101 10/26/1990 11/02/1990 $150 $0 $0 A - Amendment  

Investigation Summary

Investigation Nr: 971804
Event: 10/04/1990
Employee hospitalized when arm caught in printing press

Employee #1 had removed the guard from a press in order to make adjustments to the press. When the adjustments were complete he did not replace the guard before starting the press, which is run by a jog switch when the guard is off. Shortly after, Employee #1 was adjusting the ink flow to the press and slipped and fell into the press where the guard should have been. Employee #1 was as far from the safety shut off switch as he could be but was still able to reach the switch, thus saving his own life. It took about two hours to partially dismantle the press and remove Employee #1. Employee #1 sustained broken right fingertips, a broken tendon on the right thumb, and tissue displacement of the right forearm. He underwent surgery for skin grafts, for pins to be placed in each finger, and for his thumb tendon to be reconnected. Further surgery may be necessary. Not replacing the guards after they had been removed had become a common practice.

Keywords: FRACTURE, MAINTENANCE, PRINTING PRESS, WORK RULES, SLIP, CAUGHT BY, FALL, ARM, HAND, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105606313 Hospitalized injury Bruise/Contus/Abras Printing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close