Inspection Detail
Inspection: 105598726 - Hydro Flame Corporation
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Hydro Flame Corporation
1874 Pioneer Road
Salt Lake City, UT 84104
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3433
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/07/1990
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/03/1990
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360292379 |
Investigation Summary
Employee #1 was operating a power press using hand-held tongs. The machine malfunctioned, changing from single stroke to continuous stroke. Part of the die came down on the tip of the tongs, causing the hand grip to crush the employee's finger. It was later discovered that a broken rotary limit switch had caused the machine to change modes.
Keywords: DIE, POWER PRESS, FINGER, EQUIPMENT FAILURE, CRUSHED, TONGS, HAND TOOL, PRESS OPERATOR, MECH MALFUNCTION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 105598726 | Hospitalized injury | Other | Punching and stamping press machine operators |