Inspection Detail
Inspection: 105597496 - Sweethart Product Inc.
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Sweethart Product Inc.
1979 Wall Avenue
Ogden, UT 84401
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5148
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/07/1989
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/20/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360292262 |
Investigation Summary
The employer had installed two fans to pull cool air from the cooler into the process room, where ten employees worked. A propane-powered forklift was being operated in the cooler and the fans were pulling air and carbon monoxide from the cooler to the process room. Ten employees became ill at work; four employees were taken to the hospital, but only Employee #1 was admitted due to carbon monoxide poisoning. The propane-powered forklift was replaced with an electric-powered unit and the problem was resolved.
Keywords: VENTILATION, TOXIC ATMOSPHERE, INDUSTRIAL TRUCK, POISONING, TOXIC FUMES, CARBON MONOXIDE, PROPANE TRUCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 105597496 | Hospitalized injury | Poisoning(Systemic) | Miscelaneous food preparation occupations |