Powered by GoogleTranslate

Inspection Detail

Inspection: 105572580 - J & M Industries Inc

Inspection Information - Office: Tennessee Osha Nashville Office - Safety

 

Inspection Nr: 105572580
Report ID: 0454712
Date Opened: 07/06/1988

Site Address:
J & M Industries Inc
10th & Shelby Street
Nashville, TN 37206

Mailing Address:
P. O. Box 606, Leeds, AL 35094

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/06/1988

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/04/1988


Related Activity
Type Activity Nr Safety Health
Accident 360778690
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $2,000 $0 $0 $0 $0 $2,000
Current Penalty $2,000 $0 $0 $0 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260404 B01 I 07/13/1988 07/16/1988 $1,000 $1,000 $0 -  
2. 01002 Serious 19260404 F06 07/13/1988 07/16/1988 $1,000 $1,000 $0 -  

Investigation Summary

Investigation Nr: 978494
Event: 07/05/1988
ELECTRIC SHOCK - GROUND FAULT IN CORD SET

AN EMPLOYEE WAS INSTALLING METAL FASCIA PANELS ON THE FRONT OF A SINGLE STORY BUILDING. AN EXTENSION CORD SET BEING USED ON THE JOBSITE HAD A GROUND FAULT (THE UNGROUNDED CONDUCTOR WAS CONTACTING THE EQUIPMENT GROUNDING CONDUCTOR). ADDITIONALLY, THE GROUNDING BLADE FOR THE ATTACHMENT PLUG ON THE CORD SET HAD BEEN REMOVED. THE EMPLOYEE WAS ELECTROCUTED WHEN HE PICKED UP AN ATTACHMENT PLUG WITH A METAL HOUSING. THE HOUSING WAS ENERGIZED BY THE GROUND FAULT AND LACK OF PROPER GROUNDING IN THE EXTENSION CORD SET.

Keywords: E GI V, ELECTRICAL, CORD SET, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, EQUIPMENT GROUNDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105572580 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close