Powered by GoogleTranslate

Inspection Detail

Inspection: 105503676 - Synair Corp

Inspection Information - Office: Tennessee Osha Chattanooga Office - Health

 

Inspection Nr: 105503676
Report ID: 0454723
Date Opened: 12/11/1987

Site Address:
Synair Corp
2003 Amnicola Hwy.
Chattanooga, TN 37406

Mailing Address:
P.O. Box 5269, Chattanooga, TN 37406

Union Status: NonUnion

SIC:2821

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 12/18/1987

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 03/31/1988


Related Activity
Type Activity Nr Safety Health
Accident 360285407
Complaint 71599708 Yes
Referral 900802570 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 3 2 5
Initial Penalty $1,260 $0 $0 $0 $0 $1,260
Current Penalty $1,260 $0 $0 $0 $0 $1,260
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100134 B01 01/20/1988 03/21/1988 $420 $420 $0 -  
2. 01001B Serious 19100134 B02 01/20/1988 03/21/1988 $0 $0 $0 -  
3. 01001C Serious 19100134 B03 01/20/1988 03/21/1988 $0 $0 $0 -  
4. 01001D Serious 19100134 B07 01/20/1988 03/21/1988 $0 $0 $0 -  
5. 01002A Serious 19100134 D02 I 01/20/1988 02/19/1988 $420 $420 $0 -  
6. 01002B Serious 19100134 D02 II 01/20/1988 02/19/1988 $0 $0 $0 -  
7. 01003A Serious 19100134 E03 01/20/1988 03/21/1988 $420 $420 $0 -  
8. 01003B Serious 19100134 E03 I 01/20/1988 02/19/1988 $0 $0 $0 -  
9. 01003C Serious 19100134 E03 III 01/20/1988 03/22/1988 $0 $0 $0 P - Petition to Mod Abatement  
10. 02001 Other 19101200 E01 II 01/20/1988 03/21/1988 $0 $0 $0 -  
11. 02002 Other 19101200 F04 I 01/20/1988 02/19/1988 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 977629
Event: 12/11/1987
One employee killed, one injured by toxic vapors

Employee #1 entered a tank (confined space) containing 1,1,1-trichloroethane and was overcome by the toxic fumes. Employee #2, a management official who attempted to rescue him, had to be dragged from the tank after he was also overcome. Employee #1 died of asphyxia. The protective respiratory equipment used for this operation was the wrong type for use in a confined space. The workplace atmosphere was not tested prior to entry, and safety harnesses and lifelines were not available.

Keywords: TRICHLOROETHANE, ASPHYXIATED, PPE, WORK RULES, TOXIC ATMOSPHERE, INHALATION, SCBA, OVEREXPOSURE, TANK, CONFINED SPACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105503676 Non Hospitalized injury Asphyxia Managers and administrators, n.e.c
2 105503676 Fatality Asphyxia Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.