Powered by GoogleTranslate

Inspection Detail

Inspection: 105491104 - East-Pak A Division Of Eastern Distribution, Inc.

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 105491104
Report ID: 0454510
Date Opened: 04/25/1989

Site Address:
East-Pak A Division Of Eastern Distribution, Inc.
Ashmore Branch Road
Greenville, SC 29606

Mailing Address:
P.O. Box 5702 - Station B, Greenville, SC 29606

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/14/1989

Emphasis:

Case Closed: 11/29/1989


Related Activity
Type Activity Nr Safety Health
Accident 360283329
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $480 $0 $0 $0 $0 $480
Current Penalty $240 $0 $0 $0 $0 $240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19101000 A02 08/04/1989 09/07/1989 $240 $480 $0 I - Informal Settlement  
2. 01001B Serious 19101000 E 08/04/1989 09/07/1989 $0 $0 $0 I - Informal Settlement  
3. 02001 Other 19100178 P01 08/04/1989 09/07/1989 $0 $0 $0 I - Informal Settlement  
4. 02002 Other 19101200 E01 08/04/1989 09/07/1989 $0 $0 $0 I - Informal Settlement  
5. 02003 Other 19101200 E01 I 08/04/1989 09/07/1989 $0 $0 $0 I - Informal Settlement  
6. 02004 Other 19101200 H 08/04/1989 09/07/1989 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 674077
Event: 04/24/1989
THREE EMPLOYEES OVEREXPOSED TO CARBON MONOXIDE

On April 12, 1989, Employee #1 informed management that employees were experiencing headaches and dizziness at their workstations. On April 23, 1989, Employee #1 experienced throat irritation, dizziness and a headache. While driving home at 6:00 p.m., Employee #1 sought medical attention at the emergency room. Employee #1 was examined and disclosed the source of exposure to the attending physician who called Employee #1's employer and asked him to evacuate the building at 7:30 p.m. The building is 30,000 square feet with 36-foot high ceilings at the apex. The building was evacuated and some second-shift employees requested and required medical attention. Employees #2 and #3 were most affected and had the highest exposure after being on the job 3 hours. All affected employees were operating packaging equipment while a propane-powered forklift operated in the area. Carbon monoxide poisoning from the propane-powered forklift was determined to be the source of exposure.

Keywords: INDUSTRIAL TRUCK, CARBON MONOXIDE, PROPANE TRUCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105491104 Non Hospitalized injury Poisoning(Systemic) Weighers, measurers and checkers
2 105491104 Non Hospitalized injury Poisoning(Systemic) Weighers, measurers and checkers
3 105491104 Non Hospitalized injury Poisoning(Systemic) Weighers, measurers and checkers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close