Inspection Detail
Inspection: 105447015 - Quantum Constructors Inc.
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Quantum Constructors Inc.
1101 Gervais Street
Columbia, SC 29201
Mailing Address:
800 West 18th Street, Connersville, IN 47331
Union Status: NonUnion
SIC:1791
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/07/1987
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/24/1987
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360775530 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $1,610 | $0 | $0 | $0 | $0 | $1,610 |
Current Penalty | $402 | $0 | $0 | $0 | $0 | $402 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260104 C | 04/29/1987 | 05/02/1987 | $140 | $560 | $0 | 05/26/1987 | F - Formal Settlement | |
2. | 01002 | Serious | 19260451 A04 | 04/29/1987 | 05/02/1987 | $122 | $490 | $0 | 05/26/1987 | F - Formal Settlement | |
3. | 01003A | Serious | 19260451 A07 | 04/29/1987 | 05/02/1987 | $140 | $560 | $0 | 05/26/1987 | F - Formal Settlement | |
4. | 01003B | Serious | 19260451 A12 | 04/29/1987 | 05/02/1987 | $0 | $0 | $0 | 05/26/1987 | F - Formal Settlement |
Investigation Summary
Employee #1 was approximately 200 feet (18 stories) above the ground on a 24 ft long R.D. Werner bracket scaffold, model 3224, installing siding. The scaffold collapsed and Employee #1 fell. He sustained multiple injuries and was killed. The scaffold bracket which broke and all other brackets used with this system were made without engineering plans and were improperly welded. The scaffold boards were not belted to the brackets. The safety line (rope) was in poor condition and was not a wire rope, which it should have been because the rope is exposed to potential abrasion.
Keywords: LIFELINE, INADEQUATE MAINT, UNSECURED, WORK RULES, BROKEN WELD, CONSTRUCTION, EQUIPMENT FAILURE, SCAFFOLD COLLAPSE, FALL, FALL PROTECTION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 105447015 | Fatality | Fracture | Construction trades, n.e.c. |