Powered by GoogleTranslate

Inspection Detail

Inspection: 105442784 - Hill Electric Co., Inc.

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 105442784
Report ID: 0454510
Date Opened: 09/03/1987

Site Address:
Hill Electric Co., Inc.
Jackson Street
Barnwell, SC 29812

Mailing Address:
P. O. Box 1366, Anderson, SC 29622

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 09/18/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/08/1988


Related Activity
Type Activity Nr Safety Health
Accident 360280234
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 19260404 F06 10/13/1987 10/16/1987 $0 $0 $0 11/05/1987 F - Formal Settlement  
2. 01001B Other 19260404 A01 10/13/1987 10/16/1987 $0 $0 $0 11/05/1987 F - Formal Settlement  

Investigation Summary

Investigation Nr: 801837
Event: 09/03/1987
ELECTRIC SHOCK - MISWIRED ATTACHMENT PLUG

AN ELECTRICIAN HAD REPLACED THE ATTACHMENT PLUG FOR THE POWER SUPPLY CORD ON A MILLER DIAL ARC 250 AC/DC WELDER. THE CORD CONTAINED ONLY THREE CONDUCTORS: ONE BLUE AND ONE ORANGE CONDUCTOR, WHICH HE CONNECTED TO THE TWO CURRENT CARRYING PINS ON THE PLUG, AND ONE "BARE" ONE, WHICH HE CONNECTED TO THE GROUNDING PIN. SHORTLY, AFTER THE REPAIR, A WELDER TURNED ON THE WELDING MACHINE TO PERFORM SOME WORK. WHEN THE WELDER ATTEMPTED TO ATTACH THE GROUND LEAD, HE RECEIVED AN ELECTRIC SHOCK. HE CALLED THE ELECTRICIAN TO TURN THE MACHINE OFF. THE ELECTRICIAN WAS ELECTROCUTED WHEN HE CONTACTED THE FRAME OF THE WELDING MACHINE. AN INSPECTION OF THE INTERNAL WIRING OF THE WELDING MACHINE SHOWED THAT THE ORANGE CONDUCTOR WAS CONNECTED TO THE CHASSIS OF THE MACHINE AND THAT THE BLUE AND "BLACK" CONDUCTORS WERE THE CURRENT CARRYING CONDUCTORS. THUS, THE ELECTRICIAN HAD CONNECTED THE EQUIPMENT GROUNDING CONDUCTOR DIRECTLY TO AN ENERGIZED LINE.

Keywords: ELECTRICAL, E GI VII, ATTACHMENT PLUG, GROUND FAULT, EQUIPMENT GROUNDING, ELECTROCUTED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105442784 Fatality Electric Shock Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.