Inspection Detail
Inspection: 104690029 - American Truck Wash
Inspection Information - Office: Nv-E-Reno 0953210
Site Address:
American Truck Wash
655 South Stanford Way
Sparks, NV 89431
Mailing Address:
655 South Stanford, Sparks, NV 89431
Union Status: NonUnion
SIC:7542
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 12/05/1988
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 01/27/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360762017 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $180 | $0 | $0 | $0 | $0 | $180 |
| Current Penalty | $180 | $0 | $0 | $0 | $0 | $180 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100133 A01 | 12/20/1988 | 12/23/1988 | $180 | $180 | $0 | - |
Investigation Summary
Employee #1 sustained minor chemical burns when a hose line pressurized at 60 lb psi burst open and sprayed him with a dilute acid solution.
Keywords: EQUIPMENT FAILURE, HOSE, RUPTURE, HIGH PRESSURE, CHEMICAL BURN, ACCIDENTAL DISCHARGE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 104690029 | Non Hospitalized injury | Burn(Chemical) | Vehicle washers and equipment cleaners |
Translate