Powered by GoogleTranslate

Inspection Detail

Inspection: 104611249 - Paul'S Plumbing & Combustion Equipment Co

Inspection Information - Office: Nv-E-Reno 0953210

 

Inspection Nr: 104611249
Report ID: 0953210
Date Opened: 07/28/1987

Site Address:
Paul'S Plumbing & Combustion Equipment Co
Filbert Dr & Peckham Ln
Reno, NV 89502

Mailing Address:
1808 Frazier Ave, Sparks, NV 89431

Union Status: NonUnion

SIC:1711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/31/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/10/1987


Related Activity
Type Activity Nr Safety Health
Accident 360761704

Investigation Summary

Investigation Nr: 14236764
Event: 07/28/1987
Employee burned in gas explosion

Employee #1 was using a gas torch and solder to install a fitting on a water meter. The gas line near the water meter exploded, causing a fire. Employee #1 sustained burns on both arms, his back, and the side of his face. He was hospitalized.

Keywords: BURN, WORK RULES, FIRE, CONSTRUCTION, GAS, BACK, EXPLOSION, ARM, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104611249 Hospitalized injury Burn/Scald(Heat) Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.