Inspection Detail
Inspection: 1045946.015 - Mastec North America, Inc.
Inspection Information - Office: Tampa Area Office
Site Address:
Mastec North America, Inc.
3210 S. Tropical Trail
Merritt Island, FL 32953
Mailing Address:
5380 Capital Circle Nw, Tallahassee, FL 32303
Union Status: NonUnion
SIC:
NAICS: 237130/Power and Communication Line and Related Structures Construction
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/11/2015
Emphasis:
Case Closed: 04/30/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 967952 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260960 C01 III B | 09/08/2015 | $0 | $7,000 | $0 | 09/14/2015 | R - Review Commission | Citation has been deleted. |
Investigation Summary
At 2:55 p.m. on March 10, 2015, an employee was working from the basket of a truck aerial lift, re-installing power distribution lines onto the concrete pole cross arm. The employee was electrocuted when the energized lines not properly insulated made contact and electrocuted the employee.
Keywords: Aerial Lift, Electrocuted, Power Lines
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1045946.015 | 40 | M | Fatality | Electrical power installers and repairers |
Translate