Inspection Detail
Inspection: 104528906 - Cable Construction, Inc.
Inspection Information - Office: Minnesota Department Of Labor And Industry
Site Address:
Cable Construction, Inc.
Thrope Ave.
Ada, MN 56510
Mailing Address:
1044 E. Washington St., Ely, MN 55731
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/17/1987
Emphasis:
Case Closed: 12/20/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360760136 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | 4 | |||
| Current Violations | 2 | 2 | 4 | |||
| Initial Penalty | $142 | $0 | $0 | $0 | $0 | $142 |
| Current Penalty | $142 | $0 | $0 | $0 | $0 | $142 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260950 B02 | 09/01/1987 | 09/04/1987 | $116 | $116 | $0 | - | ||
| 2. | 01002 | Serious | 19260601 B04 | 09/01/1987 | 09/29/1987 | $26 | $26 | $0 | - | ||
| 3. | 02001 | Other | 19260600 A03 II | 09/01/1987 | 09/08/1987 | $0 | $0 | $0 | - | ||
| 4. | 02002 | Other | 19260556 B02 IX | 09/01/1987 | 09/08/1987 | $0 | $0 | $0 | - |
Investigation Summary
AN ELECTRICAL WORKER CLIMBED A UTILITY POLE AND CONTACTED AN ENERGIZED 2400-VOLT OVERHEAD POWER LINE. HIS FOREMAN HAD TOLD HIM EARLIER TO WAIT, AS THE LINES HAD NOT YET BEEN DEENERGIZED.
Keywords: ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LOCKOUT, E PTD, ELEC UTILITY WORK, UTILITY POLE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 104528906 | Fatality | Electric Shock | Misc. electrical & electronic equipment repairers |