Powered by GoogleTranslate

Inspection Detail

Inspection: 104438262 - New Jersey Fireworks Mfg. Co., Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 104438262
Report ID: 0352410
Date Opened: 10/15/1991

Site Address:
New Jersey Fireworks Mfg. Co., Inc.
1600 Old Philadelphia Road
Elkton, MD 21922

Mailing Address:
Po Box 217, Elkton, MD 21922

Union Status: NonUnion

SIC:2899

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/02/1992

Planning Guide: Safety-Manufacturing

Emphasis: N:Fireworks

Case Closed: 05/05/1992


Related Activity
Type Activity Nr Safety Health
Accident 360211130
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 2 3 5
Initial Penalty $2,300 $0 $0 $0 $0 $2,300
Current Penalty $500 $0 $0 $0 $0 $500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 50104 A 04/10/1992 04/15/1992 $250 $570 $0 I - Informal Settlement  
2. 03001 Serious 19100106 D02 1 04/10/1992 04/15/1992 $250 $580 $0 I - Informal Settlement  
3. 03002 Other 19100106 E06 I 04/10/1992 04/15/1992 $0 $580 $0 I - Informal Settlement  
4. 04001 Other 19101200 H 04/10/1992 04/15/1992 $0 $570 $0 I - Informal Settlement  
5. 05001 Other 50405 B03 04/10/1992 04/15/1992 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14298848
Event: 10/14/1991
Flammable vapors explode, employee not injured

Employee #1 was working in the fuse building preparing and threading the machines for the next day's production. He had prepared the machines by adding a lacquer coating for the fuse and acetone to keep the lacquer from hardening. Once this was accomplished, Employee #1 swept the floor and placed the sweepings into a box beneath the table. He then proceeded to wash his hands in a 5-gallon container of acetone with approximately 1 to 2 gallons inside. An unknown ignition source ignited the vapors from the lacquer and acetone, resulting in a fire and explosion. Both substances have a flash point of 0 degrees Fahrenheit. A secondary explosion occurred. It is believed that this explosion originated in the box of sweepings, which contained a mixture of black powder and sawdust. Prior to the initial explosion Employee #1 noticed a trail of fire coming across the floor. He jumped out the door as the explosion occurred. Employee #1 had little training in his 2 months of employment.

Keywords: SAWDUST, VAPOR, FLAMMABLE VAPORS, LOW FLASH POINT, LACQUER, FIRE, ACETONE, EXPLOSION, POWDER, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104438262 Non Hospitalized injury Burn(Chemical) Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close