Powered by GoogleTranslate

Inspection Detail

Inspection: 104435912 - Chemetals, Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 104435912
Report ID: 0352450
Date Opened: 11/08/1990

Site Address:
Chemetals, Inc.
711 Pittman Road
Baltimore, MD 21226

Mailing Address:
, , 00000

Union Status: Union

SIC:3313

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 02/28/1991

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 04/22/1991


Related Activity
Type Activity Nr Safety Health
Accident 360758296
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $1,125 $0 $0 $0 $0 $1,125
Current Penalty $565 $0 $0 $0 $0 $565
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A 3 II 03/27/1991 03/30/1991 $340 $675 $0 I - Informal Settlement  
2. 02001A Serious 19100252 A 2 IV 03/27/1991 03/30/1991 $225 $450 $0 I - Informal Settlement  
3. 02001B Serious 19100252 A 2 VIII 03/27/1991 03/30/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 825695
Event: 11/03/1990
Employee's fingertip amputated by blender blade

Employee #1, the operator of a cynate mixer, had just emptied the unit and was preparing to clear off the gate valve seat. Normally, the operator cleans the seat and greases the joint to get a watertight seal. Employee #1 used his fingers instead of a wire brush to clean the seal. While he was clearing the seal, the blender blade was still rotating within the unit. Employee #1's fingers contacted the blade; one fingertip was cut and another finger was partially amputated. Employee #1 was given first aid and taken to Union Memorial Hospital for treatment.

Keywords: MIXER BLADE, ROTATING PARTS, AMPUTATED, FINGER, WORK RULES, CLEANING, EQUIPMENT OPERATOR, MIXER, LOCKOUT, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104435912 Hospitalized injury Amputation Mixing and blending machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.