Inspection Detail
Inspection: 104388657 - Rockville Service Center
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Rockville Service Center
1610 Gaither Rd
Rockville, MD 20850
Mailing Address:
1900 Penn Ave, N. W., Washington, MD 20068
Union Status: Union
SIC:4911
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/22/1988
Emphasis: L:4900
Case Closed: 12/28/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360214159 |
Investigation Summary
An employee was in a training class for climbing utility poles. She was practicing rotating around the pole. Her pole climber cut out; and she fell, with her positioning strap around the pole, about 7.6 meters to hard compact soil. She sustained multiple fractures and was hospitalized for her injuries.
Keywords: FRACTURE, POWER LINE WORKER, INEXPERIENCE, ELEC UTILITY WORK, FALL, FALL PROTECTION, CUTOUT--GAFF
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 104388657 | Hospitalized injury | Fracture | Electrical power installers and repairers |
Translate