Powered by GoogleTranslate

Inspection Detail

Inspection: 104363502 - Advanced Koncrete Pumping Service Inc

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 104363502
Report ID: 0352440
Date Opened: 03/19/1991

Site Address:
Advanced Koncrete Pumping Service Inc
2209 Cool Spring Road
Adelphi, MD 20783

Mailing Address:
8705 Gunston Place, Welcome, MD 20693

Union Status: Union

SIC:1799

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/17/1991

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/06/1991


Related Activity
Type Activity Nr Safety Health
Accident 360755060
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 5 9
Current Violations 4 5 9
Initial Penalty $0 $25,400 $0 $0 $0 $25,400
Current Penalty $0 $2,905 $0 $0 $0 $2,905
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Willful 19260416 A01 05/08/1991 05/11/1991 $635 $6,350 $0 I - Informal Settlement  
2. 02001 Willful 19260416 A03 05/08/1991 05/11/1991 $635 $6,350 $0 I - Informal Settlement  
3. 03001 Willful 19260416 A03 05/08/1991 05/11/1991 $635 $6,350 $0 I - Informal Settlement  
4. 04001 Willful 19260416 A03 05/08/1991 05/11/1991 $1,000 $6,350 $0 I - Informal Settlement  
5. 05001 Other 19101200 E01 05/08/1991 05/11/1991 $0 $0 $0 -  
6. 05002 Other 19101200 G01 05/08/1991 05/11/1991 $0 $0 $0 -  
7. 05003 Other 19101200 H 05/08/1991 05/11/1991 $0 $0 $0 -  
8. 05004 Other 890032 D B 05/08/1991 05/11/1991 $0 $0 $0 -  
9. 05005 Other 890032 E A 05/08/1991 05/11/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 891648
Event: 03/19/1991
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Some employees were using a 1985 Pecco Putzmeistr concrete pumping truck (Model No. PMP 150P-8-M32/28, Serial No. 588) to pour concrete for footers at a single-family residence. The boom of the pumping truck was positioned over a 7620-volt overhead power line running alongside the street. One of the employees was handling the hose at the discharge end of the boom. The boom was within 0.6 meters of one of the phase conductors of the power line. Apparently, the wind blew the conductor into the boom and energized the truck. The employee handling the hose was electrocuted. The employees had received no safety training, and their employer had not contacted the electric utility owning the power line to deenergize or guard the line.

Keywords: ELECTRICAL, E GI IA, TRUCK BOOM, UNTRAINED, ELECTROCUTED, OVERHEAD POWER LINE, CONCRETE TRUCK, BOOM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104363502 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.