Inspection Detail
Inspection: 104302674 - Jones Plastic & Engineering Co., Llc
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
Jones Plastic & Engineering Co., Llc
2410 Plantside Drive
Jeffersontown, KY 40299
Mailing Address:
, , 00000
Union Status: Union
SIC:3089
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/04/1988
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/28/1991
Type | Activity Nr | Safety | Health |
---|---|---|---|
Complaint | 73099160 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 7 | 9 | |||
Current Violations | 1 | 7 | 8 | |||
Initial Penalty | $1,040 | $0 | $0 | $0 | $0 | $1,040 |
Current Penalty | $560 | $0 | $0 | $0 | $0 | $560 |
FTA Penalty | $3,000 | $0 | $0 | $2,000 | $0 | $5,000 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100219 F03 | 08/30/1988 | 09/19/1988 | $560 | $560 | $3,000 | 09/19/1988 | F - Formal Settlement | |
2. | 01002 | Serious | 19100305 G02 III | 08/30/1988 | 09/06/1988 | $480 | $480 | $0 | 09/19/1988 | R - Review Commission | Citation has been deleted. |
3. | 02001 | Other | 19100022 A02 | 08/30/1988 | 10/10/1988 | $0 | $0 | $0 | 09/19/1988 | R - Review Commission | |
4. | 02002 | Other | 19100022 B01 | 08/30/1988 | 10/10/1988 | $0 | $0 | $0 | 09/19/1988 | R - Review Commission | |
5. | 02003 | Other | 19100023 A08 II | 08/30/1988 | 09/06/1988 | $0 | $0 | $1,000 | 09/19/1988 | F - Formal Settlement | |
6. | 02004 | Other | 19100023 C01 | 08/30/1988 | 10/10/1988 | $0 | $0 | $0 | 09/19/1988 | R - Review Commission | |
7. | 02005 | Other | 19100023 D01 III | 08/30/1988 | 10/10/1988 | $0 | $0 | $1,000 | 09/19/1988 | F - Formal Settlement | |
8. | 02006 | Other | 19100178 P01 | 08/30/1988 | 10/10/1988 | $0 | $0 | $0 | 09/19/1988 | R - Review Commission | |
9. | 02007 | Other | 19100305 G01 I | 08/30/1988 | 09/06/1988 | $0 | $0 | $0 | 09/19/1988 | R - Review Commission |
Investigation Summary
TWO, APPARENTLY UNRELATED, ACCIDENTS ARE COVERED BY THIS REPORT. ONE EMPLOYEE RECEIVED AN ELECTRIC SHOCK FROM AN ELECTRIC CORD THAT WAS LYING IN WATER. THE OTHER EMPLOYEE RECEIVED AN ELECTRIC SHOCK WHEN HE UNPLUGGED A HEATER CONTROLLER FROM A MACHINE. THE SECOND EMPLOYEE WAS HOSPITALIZED FOR HIS INJURY.
Keywords: E GI III, ELECTRICAL, ELECTRIC SHOCK, ELECTRIC CORD, ELEC EQUIPMENT--MISC, WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 104302674 | Non Hospitalized injury | Other | Extruding and forming machine operators | ||
2 | 104302674 | Hospitalized injury | Burn(Chemical) | Extruding and forming machine operators |