Inspection Detail
Inspection: 104302641 - Utility Consultants Inc.
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
Utility Consultants Inc.
Mets Court Apartments
Elizabethtown, KY 42701
Mailing Address:
618 Westport Road, Elilzabethtown, KY 42701
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/03/1988
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/24/1989
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360205090 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 10 | 4 | 14 | |||
Current Violations | 10 | 4 | 14 | |||
Initial Penalty | $3,850 | $0 | $0 | $0 | $0 | $3,850 |
Current Penalty | $3,850 | $0 | $0 | $0 | $0 | $3,850 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19260900 R | 09/27/1988 | 09/30/1988 | $400 | $400 | $0 | - | ||
2. | 01001B | Serious | 19260906 D | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
3. | 01001C | Serious | 19260906 Q | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
4. | 01002A | Serious | 19260902 D | 09/27/1988 | 09/30/1988 | $350 | $350 | $0 | - | ||
5. | 01002B | Serious | 19260904 A | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
6. | 01003 | Serious | 19260900 A | 09/27/1988 | 09/30/1988 | $400 | $400 | $0 | - | ||
7. | 01004A | Serious | 19260900 K | 09/27/1988 | 09/30/1988 | $400 | $400 | $0 | - | ||
8. | 01004B | Serious | 19260900 O | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
9. | 01004C | Serious | 19260906 C | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
10. | 01005A | Serious | 19260652 B | 09/27/1988 | 09/30/1988 | $400 | $400 | $0 | - | ||
11. | 01005B | Serious | 19260652 E | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
12. | 01005C | Serious | 19260651 I01 | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
13. | 01006 | Serious | 19260900 D | 09/27/1988 | 09/30/1988 | $400 | $400 | $0 | - | ||
14. | 01007 | Serious | 19260900 K03 I | 09/27/1988 | 09/30/1988 | $400 | $400 | $0 | - | ||
15. | 01008 | Serious | 19260902 H | 09/27/1988 | 09/30/1988 | $350 | $350 | $0 | - | ||
16. | 01009 | Serious | 19260905 H | 09/27/1988 | 09/30/1988 | $400 | $400 | $0 | - | ||
17. | 01010 | Serious | 19260905 P | 09/27/1988 | 09/30/1988 | $350 | $350 | $0 | - | ||
18. | 02001 | Other | 19260901 D | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
19. | 02002 | Other | 19260905 T | 09/22/1988 | 09/25/1988 | $0 | $0 | $0 | - | ||
20. | 02003 | Other | 19260905 T | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - | ||
21. | 02004 | Other | 19260909 B | 09/27/1988 | 09/30/1988 | $0 | $0 | $0 | - |
Investigation Summary
Employees were using a meter to test electric blasting caps. The meter caused unintended discharge of the explosives, and Employee #1 was killed and Employees #2 and #3 were hospitalized. Employee #4 suffered only minor injuries.
Keywords: EXPLOSIVES, CONSTRUCTION, EQUIPMENT FAILURE, EXPLOSION, ACCIDENTAL DISCHARGE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 104302641 | Fatality | Other | Plumbers, pipefitters and steamfitters | ||
2 | 104302641 | Hospitalized injury | Bruise/Contus/Abras | Plumbers, pipefitters and steamfitters | ||
3 | 104302641 | Hospitalized injury | Bruise/Contus/Abras | Plumbers, pipefitters and steamfitters | ||
4 | 104302641 | Non Hospitalized injury | Other | Plumbers, pipefitters and steamfitters |