Powered by GoogleTranslate

Inspection Detail

Inspection: 104289616 - Standard Gravure Corporation

Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance

 

Inspection Nr: 104289616
Report ID: 0452110
Date Opened: 11/11/1988

Site Address:
Standard Gravure Corporation
643 S. Sixth St.
Louisville, KY 40202

Mailing Address:
, , 00000

Union Status: Union

SIC:2754

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 02/09/1989

Emphasis:

Case Closed: 06/15/1990


Related Activity
Type Activity Nr Safety Health
Accident 360108401
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 1 4
Current Violations 1 2 1 4
Initial Penalty $490 $0 $280 $0 $0 $770
Current Penalty $490 $0 $140 $0 $0 $630
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Repeat 19101200 F05 I 03/22/1989 03/28/1989 $70 $140 $0 03/30/1989 R - Review Commission  
2. 01002 Repeat 19101200 F05 II 03/22/1989 03/28/1989 $70 $140 $0 03/30/1989 R - Review Commission  
3. 02001 Serious 19260058 L02 03/22/1989 03/28/1989 $490 $490 $0 03/30/1989 R - Review Commission  
4. 03001 Other 19101200 G01 03/22/1989 03/28/1989 $0 $0 $0 03/30/1989 R - Review Commission  

Investigation Summary

Investigation Nr: 784280
Event: 11/10/1988
Employees injured in third press explosion

Employees #1 and #2 were rewebbing the B-Red portion of a press when a flash fire started. The carbon dioxide suppression system extinguished the fire. During the fire, Employee #2 jumped over the drive shaft and hit a lever, releasing ink onto the floor. The firemen arrived to extinguish any existing fire. When they used high pressure carbon dioxide to put out the smoldering paper, it fell into the ink and started a second explosion and fire. The carbon dioxide system was engaged, but did not extinguish the fire. A half hour later, a third explosion, the biggest and most devastating, occurred. Employees #1 through #20 were injured either by the fire or by stampeding men.

Keywords: FIRE EXT SYSTEM, FIRE, EXPLOSION, PAPER, CARBON DIOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104289616 Hospitalized injury Heat Exhaustion Printing machine operators
2 104289616 Hospitalized injury Heat Exhaustion Printing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close