Powered by GoogleTranslate

Inspection Detail

Inspection: 104237383 - Fort Dodge Ice & Cold, L.C.

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 104237383
Report ID: 0751910
Date Opened: 05/24/1989

Site Address:
Fort Dodge Ice & Cold, L.C.
2472 170th Street
Fort Dodge, IA 50501

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:4222

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/02/1989

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/30/1989


Related Activity
Type Activity Nr Safety Health
Accident 360741243
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 4 6
Current Violations 2 4 6
Initial Penalty $600 $0 $0 $0 $0 $600
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B02 06/06/1989 06/11/1989 $300 $300 $0 -  
2. 01002 Serious 19100303 G01 06/06/1989 06/11/1989 $300 $300 $0 -  
3. 02001 Other 40008 06/06/1989 06/14/1989 $0 $0 $0 -  
4. 02002 Other 1200003 1 06/06/1989 07/12/1989 $0 $0 $0 -  
5. 02003 Other 1200005 1 06/06/1989 07/12/1989 $0 $0 $0 -  
6. 02004 Other 1200006 06/06/1989 07/12/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 1001429
Event: 05/17/1989
ELECTRIC SHOCK - DIRECT CONTACT WITH ELECTRIC CONDUCTOR

AN EMPLOYEE WAS LOOKING FOR A REFRIGERANT LEAK IN A BOHN E SERIES REFRIGERATION UNIT. THE EMPLOYEE REMOVED THE UNIT'S ELECTRICAL PANEL WHILE IT REMAINED ENERGIZED. AS HE WAS WORKING, HE RECEIVED AN ELECTRIC SHOCK AND DIED OF CARDIAC DYSRHYTHMIA.

Keywords: MAINTENANCE, E GI IV, ELECTRICAL, ELECTROCUTED, MECHANIC, LOCKOUT, ELECTRICAL BOX

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104237383 Fatality Electric Shock Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.