Inspection Detail
Inspection: 104234927 - Cryder Well Co.
Inspection Information - Office: Iowa 0751910
Site Address:
Cryder Well Co.
East Front Street
Clare, IA 50524
Mailing Address:
Route 5, Fort Dodge, IA 50501
Union Status: NonUnion
SIC:1781
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/10/1989
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/10/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360741375 |
Investigation Summary
THE MAYOR OF A SMALL TOWN CALLED A WATER WELL COMPANY TO REPAIR THE CITY WATER PUMP. THE WELL COMPANY OWNER WAS ITS ONLY EMPLOYEE, SO THE MAYOR ASSISTED HIM. THE PUMP HAD TO BE REMOVED FROM THE WELL SO THAT REPAIRS COULD PROCEED. THE PROPRIETOR USED A BOOM TRUCK SO THAT THE PUMP COULD BE LIFTED THROUGH THE ROOF OF THE WELL HOUSE. WHILE HE WAS MOVING THE BOOM INTO POSITION, IT CONTACTED AN OVERHEAD POWER LINE. THE MAYOR, WHO WAS TOUCHING THE TRUCK AT THE TIME, WAS ELECTROCUTED. THE PROPRIETOR, WHO WAS OPERATING THE CONTROLS, RECEIVED AN ELECTRIC SHOCK AND BURNS. HE WAS HOSPITALIZED FOR HIS INJURIES.
Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTRIC SHOCK, TRUCK BOOM, BURN, BOOM, ELECTROCUTED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 104234927 | Hospitalized injury | Electric Shock | Supervisors, n.e.c. |