Powered by GoogleTranslate

Inspection Detail

Inspection: 104223789 - M. P. Kluck Construction

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 104223789
Report ID: 0751910
Date Opened: 11/18/1988

Site Address:
M. P. Kluck Construction
R. R. 1, Hurstville
Maquoketa, IA 52060

Mailing Address:
P. O. Box 1045, Highway 20, Dubuque, IA 52001

Union Status: Union

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/01/1988

Emphasis:

Case Closed: 03/15/1993


Related Activity
Type Activity Nr Safety Health
Accident 360740963
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $350 $0 $0 $0 $0 $350
Current Penalty $350 $0 $0 $0 $0 $350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 01/05/1989 01/14/1989 $350 $350 $0 -  
2. 01001B Serious 19100180 J01 I 01/05/1989 12/01/1988 $0 $0 $0 -  
3. 01001C Serious 19260550 A02 01/05/1989 02/08/1989 $0 $0 $0 -  
4. 02001 Other 40002 1 01/05/1989 02/08/1989 $0 $0 $0 -  
5. 02002 Other 1200003 1 01/05/1989 02/08/1989 $0 $0 $0 -  
6. 02003 Other 1200005 2 01/05/1989 02/08/1989 $0 $0 $0 -  
7. 02004 Other 1200006 01/05/1989 02/08/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 1002500
Event: 11/15/1988
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

An employee was setting up his truck crane to remove a concrete mixer from a ready-mix concrete truck and to replace the mixer with a new one. The employee parked his truck crane directly beneath an overhead power line, got out of the truck, and went to the crane's operating station. He extended the outriggers so that he could install the pads. He then raised the boom of the crane into contact with the power line. As he exited the crane cab to install the outrigger pads, he had one hand on handle of crane cab. He was electrocuted when his foot touched the damp ground.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104223789 Fatality Electric Shock Crane and tower operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close